Digital Meter------3 Phase Voltmeter (HL-S96-5 AC 3V)
US$10.00 - 30.00 | 50 Pieces (MOQ) |
Port:
Ningbo, China
Transport Package:
Seaworthy Export Packing
Payment Terms:
L/C, T/T
Wenzhou Hutong Light Industries Co., Ltd.
Zhejiang, China
Last Login Date:
Aug 09, 2020
Business Type:
Trading Company
Find Similar Products
Product Description
Company Info
Basic Info.
Model NO.
HL-S96-5 AC 3V
Installation
General Installation Meter
Display
Usage
Meter for Industry and Home Use, Standard Electric Energy Meter
Theory
Power Source
AC and DC
DC Voltmeter Type
Electrostatic
AC Voltmeter Type
Electrostatic
Customized
Customized
Operating Temperature
-10 Degrees-+55 Degrees
Storage Temperature
-25 Degrees-+70 Degrees
Relative Humidity
<93%, Non Corrosive Gas
Insulation Resistance
>500 M Ohm
AC Withstand Voltage
>AC 2000 V
ESD
Level 4
Surge
Level 4
Eft
Level 3
RF
Level 3
Trademark
HONLY
Origin
China
Product Description
Product Description
High enviromental tolerant ASIC for high-precision heinrich rudolf hertz measrement of single phase AC frequency.
High-brightness LED digital tubes display.
Rugged black screen printable PVC panel with temperature resistance up to 120ºC and voltage resistance up to AC 2000V.
Casing is made of high-quality, durable plastic materials. Push-click design enables simple, fool-proof installation.
Technical Data:
Accuracy
Voltage Accuracy class 0.5
Parameters
Rated voltage: AC 57.7V, AC 100V, AC 220V, AC 380V
Rated current: AC 5V, AC 1A
Overload Rating Current: 1.2X rating (continous)
10 X rating for 5 secods
Overload Rating voltage: 1.2X rating (continous)
2X rating for 1 seconds
Power consumption: <4VA/phase
Internal resistance: Current<200mΩ, Voltage≥1kΩ/V
Frequency: 45~65Hz, DC
Auxiliary Power Supply
Rated power: AC/DC 48~240V, AC/DC 80~265V, AC 380V, AC 220V, AC 110V, AC 60V
Power consumpt: <4VA
Display Features
Hignlight LED Display
Display data full range 1-9999 arbitrary variable settings
Display"HHHH", when data over 1.4 times the full range.
Optional Function:
Communication function: 1 RS485 communication,
Modbus-RTU protocol, the baud rate is 1200, 2400, 4800, 9600, 19200,24000, 38400bps can be set
Passive Status Colletion:Support four-way
Passive Sensor status collection
Status/Control Signals: support four-way output voltage output (5V), 2 way alarm relay output (contact: AC250V/5A, DC30V?5A)
Analog output: support 1-way analog output conversation 4-20mA or 0~5V
Operating Environment
Operating temperature: -10ºC~+55ºC
Storage temperature:-25ºC~+70ºC
Relativi humidity< 93%, Non corrosive gas
Safety Performance
Insulation resistance:>100MΩ
AC withstand voltage:>AC 2000V
High enviromental tolerant ASIC for high-precision heinrich rudolf hertz measrement of single phase AC frequency.
High-brightness LED digital tubes display.
Rugged black screen printable PVC panel with temperature resistance up to 120ºC and voltage resistance up to AC 2000V.
Casing is made of high-quality, durable plastic materials. Push-click design enables simple, fool-proof installation.
Technical Data:
Accuracy
Voltage Accuracy class 0.5
Parameters
Rated voltage: AC 57.7V, AC 100V, AC 220V, AC 380V
Rated current: AC 5V, AC 1A
Overload Rating Current: 1.2X rating (continous)
10 X rating for 5 secods
Overload Rating voltage: 1.2X rating (continous)
2X rating for 1 seconds
Power consumption: <4VA/phase
Internal resistance: Current<200mΩ, Voltage≥1kΩ/V
Frequency: 45~65Hz, DC
Auxiliary Power Supply
Rated power: AC/DC 48~240V, AC/DC 80~265V, AC 380V, AC 220V, AC 110V, AC 60V
Power consumpt: <4VA
Display Features
Hignlight LED Display
Display data full range 1-9999 arbitrary variable settings
Display"HHHH", when data over 1.4 times the full range.
Optional Function:
Communication function: 1 RS485 communication,
Modbus-RTU protocol, the baud rate is 1200, 2400, 4800, 9600, 19200,24000, 38400bps can be set
Passive Status Colletion:Support four-way
Passive Sensor status collection
Status/Control Signals: support four-way output voltage output (5V), 2 way alarm relay output (contact: AC250V/5A, DC30V?5A)
Analog output: support 1-way analog output conversation 4-20mA or 0~5V
Operating Environment
Operating temperature: -10ºC~+55ºC
Storage temperature:-25ºC~+70ºC
Relativi humidity< 93%, Non corrosive gas
Safety Performance
Insulation resistance:>100MΩ
AC withstand voltage:>AC 2000V
Model | Parameters | Power supply | selection function | |||||
Swiching Input | Swiching Output | Relay output | Analog Outout | RS485 | Selection | |||
DP-S96-3 AC 3V | Direct AC 50V-500V AC X/57.7V AC C/100V | AC110V AC220V AC380V AC/DC 48-250V | 4 | 4 | 2 | 1 | 1 | 4/4 |
DP-S96-3 AC V | 4 | 4 | 2 | 1 | 1 | 4/4 | ||
DP-S72-3 AC V | 4 | 4 | 2 | 1 | 1 | 2/4 | ||
DP-S72-3 AC 3V | 4 | 4 | 2 | 1 | 1 | 3/4 | ||
DP-S48-3 AC V | 2 | 2 | 1 | 1 | 1 | 2/4 | ||
DP-R96*48-3 AC V | 4 | 4 | 2 | 1 | 1 | 3/4 | ||
DP-R72*36-3 AC V | 2 | 2 | 2 | 1 | 1 | 1/4 | ||
DP-S96-3 DC V | Direct DC 2V-600V | 4 | 4 | 2 | 1 | 1 | 4/4 | |
DP-S72-3 DC V | 4 | 4 | 2 | 1 | 1 | 2/4 | ||
DP-S48-3 DC V | 2 | 2 | 1 | 1 | 1 | 2/4 | ||
DP-R96*48-3 DC V | 4 | 4 | 2 | 1 | 1 | 3/4 | ||
DP-R72*36-3 DC V | 2 | 2 | 2 | 1 | 1 | 1/4 |
Model | Parameters | Power supply | selection function | ||||
Swiching Input | Relay output | Analog Outout | RS485 | Selection | |||
DP-S96-5 AC 3V | Direct AC 50V-500V AC X/57.7V AC C/100V | AC110V AC220V AC380V AC/DC 48-250V | 2 | 2 | 1 | 1 | 4/4 |
DP-S96-5 AC V | 2 | 2 | 1 | 1 | 4/4 | ||
DP-S72-5 AC V | 2 | 2 | 1 | 1 | 2/4 | ||
DP-S72-5 AC 3V | 2 | 2 | 1 | 1 | 3/4 | ||
DP-S48-5 AC V | 2 | 1 | 1 | 1 | 2/4 | ||
DP-S96-5 DC V | Direct DC 2V-600V | 2 | 2 | 1 | 1 | 4/4 | |
DP-S72-5 DC V | 2 | 2 | 1 | 1 | 2/4 | ||
DP-S48-5 DC V | 2 | 1 | 1 | 1 | 2/4 |